FREE SHIPPING OVER $20010% off code: HOME10Buy Now Pay Later AVAILABLE AT CHECKOUT

When should you replace the shut off valve under a sink?

Replace the shut off valve under your sink if the body is cracked or corroded, or if the valve cannot stop the water and its maker has no suitable repair for it. A wet handle or a drip at the hose nut calls for a closer look. If water is spraying, flowing into the wall or pooling quickly, skip the leak checks. Shut off the known upstream supply if you can reach and operate it safely. If you cannot, call your building's emergency maintenance contact or your water utility for shutoff help and arrange a plumber.

An angle stop has separate leak points at the hose nut, handle stem and inlet from the wall. Hose nut Stem at handle Wall connection Valve body Dry each joint and watch for the first bead.
Water from the hose nut can run down the outside of the valve. Look where the first new drop forms before deciding which part needs work.

Where is the drip actually starting?

Take the bottles out of the cabinet so you can see the underside of the faucet, the whole supply hose and the short pipe coming through the wall or floor. Pfister's bathroom faucet troubleshooting starts by drying the faucet, its supply lines, the drain and the angle stops. Dry the small nut where the hose meets the valve separately from the stem behind the handle. With everything still connected, watch which spot gets wet first. A strip of clean white tissue touched to one joint at a time can reveal a bead you cannot see against chrome.

Suppose the nut at the top of the valve is wet, but the stem under the handle stays dry. Run your eye up the hose. If you find fresh water above the nut, start at the higher connection. If the hose stays dry above and the bead forms right at the nut, Pfister identifies the supply connection and its seal as possible causes. Have that connection checked. A new valve body can still get wet when the same leaking hose goes back on it.

If the wet mark is farther back, look at where the supply pipe enters the valve. Closing the little handle acts on water headed toward the faucet. The pipe feeding the valve still has water pressure. A leak there needs a working shutoff farther upstream. If water emerges from behind the wall trim and you cannot see its origin, leave the trim and pipe in place for the plumber. A picture showing where water first appeared is more useful than one of the puddle below it.

Can I tell if the valve still shuts off?

Start with a working faucet. On an ordinary sink with separate hot and cold stops, check that water runs on each side before testing. Trace each faucet hose to its stop. If a handle or valve is already broken, badly corroded or leaking heavily, leave it alone and arrange upstream isolation. Before trying an intact stop, know where that upstream shutoff is and who can operate it.

Keep the hoses connected. Close both identified stops gently by hand, following the markings or instructions for those valves. If one jams, spins without reaching a stop or makes the pipe move, stop there. Leave the faucet connections assembled. A longer handle or a pair of pliers can put force into the pipe as well as the valve.

Check the spout. Open the faucet over the sink. On separate handles, open each in turn. On a conventional mixing faucet, check both ends of its temperature range. Keep your hands clear of the hot stream. Water already in the spout and hoses can run out and stop. If a stream keeps running or drops keep forming without tapering away, the faucet has an active feed. Leave both hoses attached and have the supply isolated before any work. A faucet that was already blocked or inoperative cannot confirm a shutoff this way.

Moen gives this same basic check before hose service on its MotionSense faucet: operate the faucet after closing its supplies to verify the water is off. A handle that looks closed cannot give you that information. Conversely, a spout that stops running shows what happened at the faucet outlet. It does not make the inlet side of the stop safe to take apart.

Is a leaking stem worth repairing?

If the first bead appears where the stem comes through the nut behind the handle, photograph the valve markings and the handle from the side. BrassCraft's parts drawing for its multi turn stop identifies a stem, a seal called bonnet packing and a bonnet nut. BrassCraft offers its BCSR01 stem repair kit for compatible angle and straight multi turn stops. Ask the maker to match your valve to the kit before deciding to keep the body. A similar looking oval handle on another valve gives you no assurance that the stem fits.

A cracked body is a different decision. A new stem would leave the crack in the part that holds water. BrassCraft's water stop instructions call for annual inspection and replacement when damage, deterioration or corrosion is found. That is an inspection interval for the covered products. It gives you no reason to replace a dry, working valve every year. If all you have is an old stain from a repaired faucet, dry the area and look for fresh water or actual damage to the metal. If you cannot distinguish a stain from corrosion, send the maker or plumber a close photo before operating the stop.

What needs to match if a part is replaced?

Tell the plumber where the pipe enters the cabinet, how the valve joins that pipe, and what connects to the faucet hose. A photo taken straight at the handle can hide both connections. Include a side view, the markings on the body and any label on the hose. BrassCraft's OR17 angle stop, for example, has a half inch female pipe inlet and a three eighths inch outside diameter compression outlet. Those descriptions refer to different ends of the same valve. If the pipe itself turns when touched or looks damaged beside the inlet, have the pipe assessed along with the stop.

Consider the 50 cm G3/8 option in Home And Tower's braided faucet supply hose pair. The supplier lists an M10 male stud for the faucet end and a G3/8 female nut for the valve end. Two hoses come in the package. A valve is not included. The three eighths marking on the BrassCraft example describes compression tubing, while the G3/8 marking on the hose describes a thread. The shared fraction cannot establish a match. If the outlet and seal type are unclear, use the faucet and stop makers' connector specifications before choosing a replacement hose.

Who can shut off the water for the work?

For work on the stop itself, SharkBite directs the installer to shut off the incoming supply and open a nearby faucet to relieve pressure and drain the line before removing the old stop. In a shared building, contact the manager to identify who controls your branch. If the upstream shutoff is unknown, stuck or fails to stop a continuing stream on the affected line, leave the valve and its nuts assembled. The plumber or water provider can arrange an effective shutoff before the repair starts.

After the installer restores water, have them show you that the repaired stop both closes off its faucet supply and stays dry when reopened. Watch the hose nut, the stem and the wall joint with the faucet running and again with it closed. If the cabinet stays dry but the spout keeps dripping when you close the faucet handle, follow the checks for a dripping bathroom faucet. If the water appears only when you empty the basin, the bathroom sink drain guide will help you identify the drain parts beneath it.

Drains and Plumbing Parts in stock

See all drains and plumbing parts