FREE SHIPPING OVER $20010% off code: HOME10Buy Now Pay Later AVAILABLE AT CHECKOUT
Bathroom Questions
Bathroom Questions › Vessel Sinks
Bathroom Questions › Glass Vessel Sinks
Bathroom Questions › Ceramic Vessel Sinks
Bathroom Questions › Bathroom Sinks
Bathroom Questions › Wall Mounted Sinks
Bathroom Questions › Undermount and Drop In Sinks
Bathroom Questions › Bathroom Faucets
Bathroom Questions › Waterfall Bathroom Faucets
Bathroom Questions › Single Hole Bathroom Faucets
Bathroom Questions › Widespread Bathroom Faucets
Bathroom Questions › Bathtub Faucets
Bathroom Questions › Shower Systems
An exposed retrofit column is usually easier when it can reuse a sound shower outlet and the existing mixing valve. An exposed mixer that needs two new supply connections can involve more work than replacing compatible concealed trim.
An exposed column can be an accessory downstream of your current control. You still turn the water on and set the temperature with the old handle. Mixed water then enters the column and travels to a head or hose. Delta's Emerge shower column is an example that connects at the existing shower arm supply. Check the actual mounting and clearance instructions for the chosen model. Reusing the feed does not tell you where or how the bar needs to be supported.
An exposed bar mixer is a different proposal. Hot and cold water have to arrive separately at the mixer. The GROHE exposed thermostatic bar specification shows separate supply connections and a temperature control on the bar. If all you have near the intended spot is a mixed outlet, you do not have those two supplies there. Ask the installer to draw the route before comparing the prices of the two boxes.
Identify the water entering the kit. Count the inlet connections on the installation diagram. If you find one mixed inlet, locate the control that will remain upstream.
Find the fixing points. Lay out the manufacturer's template against the wall. If a bracket lands on glass, an unsupported panel or a concealed service, have the installer revise the layout before drilling.
The body, pipework and outlet connections sit behind the finished surface. A new build with open framing can accommodate that work before the wall is closed. A finished tiled room can require access from the adjacent room, tile removal, waterproofing repair or all three. Ask who restores the wall and which finishes can actually be matched. A low fixture price tells you little about that part of the project.
| Existing condition | First option to investigate |
|---|---|
| Working mixer and one sound wall outlet | Compatible retrofit column |
| Two suitable separate supplies already visible | Documented exposed bar mixer |
| Open framing and new outlet locations | Concealed body with planned service access |
Find the valve family, check that it shuts off reliably and observe whether temperature stays steady at the existing head. A downstream column cannot repair a worn shutoff or restore missing hot water. If your current handle drips or temperature swings, include that diagnosis in the estimate. It is much easier to understand a quote when it says which fault the new hardware will actually address.
Measure from the connection shown in the column drawing to the finished ceiling, shelf and enclosure door. Include the height the head adds above the riser and space to install it. Then hang a length of cord where the hand shower hose will travel. Swing the door through its normal arc. A layout that fits a flat photograph can leave the user fighting the hose every morning.
Give both installers the same small drawing. Ask each to identify supply changes, support, sealing of any new penetration, trim, testing and finish repairs. If one can use an access panel and the other assumes tile demolition, have them explain how they will reach the joint and restore the waterproofing. A written access route makes those prices comparable.
Consider future service from both sides. A bar mixer is visible but its wall connections can still be concealed. A concealed cartridge may come out from the front once the handle and plate are removed. Ask the installer to show where each replaceable part comes out. If a fixed glass panel blocks that movement, resolve the conflict while the layout is still on paper.
For an existing valve, start with checking whether replacement trim fits. The shower system guide explains how the mixer and outlets work together.
Wall Mounted Brass Bathtub Faucet with Angled Spout and Hand Shower on a Long Plate or Round PlatesFrom €847,95
Concealed Thermostatic Shower System with Icon Push Buttons Black Face Rain Head and Hand ShowerFrom €2.557,95
Wall Mount Antique Brass Shower System with S Curve Riser 8 Inch Rain Head Hand Shower and Tub SpoutFrom €1.309,95
Wall Mounted Antique Brass Shower System with 8 Inch Sunflower Rain Head Hand Shower and Tub SpoutFrom €1.451,95
Wall Mounted Antique Brass Shower System with Carved Rosettes Hand Shower and Optional Tub SpoutFrom €825,95
Wall Mounted Antique Brass Shower System with Bell or Flat Head Hand Shower and Optional Tub SpoutFrom €813,95
Wall Mounted Carved Antique Brass Bathtub Faucet with Hand Shower Tub Spout and Slide Bar OptionsFrom €538,95
Wall Mounted Brass Bathtub Faucet with L Spout Knurled Knobs Hand Shower and Long or Round PlatesFrom €866,95
Wall Mounted Concealed Brass Bathtub Faucet with Round or Flat Spout Knurled Knobs and Hand ShowerFrom €883,95
Ceiling Mounted Rain and Waterfall Shower System with 31.5 Inch LED Head and Body Jets or Tub SpoutFrom €5.291,95
Concealed Thermostatic Shower System with Ceiling or Wall Rain Head Four Body Jets and Hand ShowerFrom €2.860,95
Ceiling Waterfall Rain Shower System with Body Jets LED Display Hand Shower and Optional Tub SpoutFrom €3.052,95