A square point drain is a good choice when the pipe can stay put and the tile can follow several slopes toward one opening. A linear drain earns its place when the channel can catch water across the low edge of the floor, especially if you want large tiles. If water is already leaking below the shower, the drain body moves in the floor, or wastewater is coming up through it, stop using the shower and have it inspected. Keep the water off while you collect the model information. For a working shower or a new build, start with the floor you actually have.

Quick answers

  • Keeping the tile? Look for a replacement grate that the maker lists for the existing frame. Changing the shape of the drain body can mean rebuilding the shower floor.
  • Starting with a bare floor? Choose the waterproofing system, mark the pipe center and draw the downhill path from each corner before choosing a grate.
  • Want an open entry? Look at the finished doorway width, the direction of the spray and the water path past the ends of the drain. A long grate alone cannot keep the bathroom dry.
  • Comparing two sizes? Separate the visible cover dimensions from the hidden body size, pipe connection, installed height and rated flow. Each answers a different question.
  • Can you reach the screen? Ask to see the grate lifted, the hair screen removed and the cover put back with the door or bench in its planned position.

What can you change without pulling up the shower floor?

In a finished shower, start with the smallest part that would solve the problem. A worn finish may call for a new cover only. If the existing shower drains well, its frame sits firmly and the floor is dry outside the enclosure, photograph the grate straight down beside a ruler. Get a second picture of any maker mark and of the fastening method. Record the outside dimensions and, for a screw held grate, the distance between screw centers. Leave the body and its seal in place.

Compare the photographs with the parts drawing for that drain, including the edge that supports the grate. Covers with the same face width can rest on different ledges. A replacement that rocks, drops into the opening, or needs bent tabs to stay put is a poor match. Schluter, for instance, says its STYLE grates do not fit the original frames in its KERDI DRAIN and KERDI LINE ranges. If the maker cannot identify the frame, keep the existing sound cover while a plumber identifies it. Keep people out of a shower with an open or unstable grate.

A factory made shower base is a different starting point from tile over a built up bed. Look for the base maker and model on the sales record or installation paperwork. Oatey's instructions for its No Caulk preformed base drain show washers and a locking ring securing the drain to the base, plus a separate gasket around the pipe. A cover measurement tells you little about those interfaces. If your base has a molded recess and a specific drain location, ask its maker for the compatible assembly before considering a cut for a new shape.

For a full floor replacement, ask what will be exposed. An installer working above a finished ceiling may have to connect the body before the base goes down. Access below can allow a different sequence. If the estimate assumes the plumber can reach the joint later, locate that access on the drawing. A closet ceiling on the other side of a beam does not necessarily give access to the coupling under the drain.

Where does water meet the drain under the tile?

Lift a decorative grate and you may see the throat that takes surface water. The joint that keeps water out of the floor is elsewhere. Ask the builder to show that joint in a section drawing, a view that slices through the floor. In a traditional tiled shower with a pan liner, the liner rests on a slope beneath an upper mortar bed. The liner rests on the drain base flange. A bolted ring presses the liner against that flange. Water that seeps through the upper mortar bed follows the slope of the liner into weep passages that open into the drain throat. Oatey's pan liner guide illustrates this arrangement for its 130 Series point drain.

In a bonded waterproofing system, the membrane lies directly under the tile setting layer. The drain has a compatible bonding surface where the membrane terminates. Schluter's Shower System Installation Handbook shows a membrane joining the bonding flange of its point drain and a collar joining the floor to its linear channel. Laticrete's HYDRO BAN Linear Drain sheet gives its own detail for waterproofing onto the metal flange. The location of the water seal and the materials used to form it belong to the chosen system.

The liner is clamped between a ring and a base flange. A groove in the ring drains the liner into the throat. A bonded membrane joins a flange immediately below the tile. Where the ring grips the liner Clamping ring Drain base flange Pan liner Through a weep groove in the ring Weep groove Open drain throat Bonded membrane under tile Membrane joint Bonding flange
The upper two views cut through different parts of the same drain. The dark liner stays between the ring and base where they clamp. At a groove, water follows the arrow above the liner into the throat. The bottom view shows where a bonded membrane meets its flange.

Take the actual membrane name and drain part number to the person installing the waterproofing. Ask for the detail that shows those components together, including the junction with the wall if the drain sits at its foot. If the proposal shows a clamping ring in the drawing but a plain rectangular body on the invoice, pause the purchase. Some systems publish a specific adapter or a threaded trough assembly. Get its name and instructions and confirm the existing base is one it accepts. A bead around the finished grate cannot supply the missing connection.

When you inherit an older shower, a photo taken during the build can settle what the bright cover hides. Look for the floor membrane approaching the drain, the pipe connection, and a wider view identifying which shower the picture shows. If the photo shows tile only, let the installer list the assembly as unknown. For a finish change, pursue a matching grate. For a leak or a change of body, ask for an inspection and a repair scope that includes restoring the waterproofing.

How will your tile reach a square opening or a channel?

Imagine a sheet of cardboard sitting on the floor. It lies flat on one sloping plane. If the floor changes direction under the sheet, one corner can hang in the air. A center point drain usually receives water from several directions. Small tiles and their joints can follow those changes. Large tiles can work around a point drain when the setter lays out cuts that follow the changes in plane. Ask to see those cuts on a drawing of the actual tile pattern, especially if a vein in the stone or a wood grain print should continue across the floor.

In these floor plans four slopes meet a square drain and one broad slope reaches a full width wall channel. Point drain Wall channel Several slopes One broad slope
The arrows trace surface water toward the dark openings. The lines running from the corners of the point drain layout mark changes of plane.

At a straight wall, a channel that receives water across the full low edge can allow one broad slope. That can preserve the face of a large tile. A short linear drain in the middle of a much wider wall leaves two pieces of floor beside its ends. Trace the low edge from each corner to the nearest opening. If the drawing takes water straight to a closed stretch of wall, the setter needs to shape those end areas or choose a different drain length or placement. A longer brass rectangle laid over the same point opening does not move either corner downhill.

With a channel away from the wall, water can approach from both sides. Picture two boards leaning down toward a line between them. A tile reaching across the line cannot follow both slopes as a single flat piece. Mark the channel and the change of direction on a full size paper tile before approving the pattern. Where two tiled areas meet beyond the end of a short channel, ask the setter how those last pieces drain and where the joint will land.

The bottom row of wall tile deserves a look too. Along the sides of a shower sloping to the back, the floor edge changes height as it approaches the drain. Colored pencil on a side elevation will show where a narrow wedge would be visible. Move a wall tile joint or discuss a suitable profile while you can still choose. Schluter's tray sheet also distinguishes trays for point drains from trays for linear drains. Trace the slope on the exact tray listed on the estimate. A rectangular outline alone cannot establish the direction it falls.

Which measurements should go on your sketch?

Draw the walls, entrance, curb if there is one, fixed glass and bench. Label each dimension with its starting surface. A carpenter measures the framed opening. A tile setter sees the space remaining after board, waterproofing, setting material and tile are in place. For a channel across a back wall, write down the expected finished width where the grate will sit. Also record the space available for the hidden flange and the ends of the channel body on the maker's drawing. Those parts can extend under wall finishes.

Laticrete's August 2025 HYDRO BAN Linear Drain sheet illustrates the distinction. Its listed lengths refer to actual grates, and its trough has a continuous flange extending around it. A listed 30 inch grate is 76 centimeters in this edition. The older May 2019 sheet printed 81 centimeters beside 30 inches. That mistake could put a 32 inch part on a shopping list. Keep the length in the units you measured, get the drawing for the exact trough, and compare the part numbers for the grate and the trough. Laticrete sells them separately.

A plan view separates the visible grate length from the hidden flange footprint and locates an offset pipe outlet. Visible grate length Outlet center Full flange footprint
Use the dimensioned plan for the exact body. Record its flange length and pipe center separately from the length of the grate.

Locate the center of the pipe from two fixed, perpendicular surfaces. Mark which faces you used and mark the outlet on the proposed drain drawing. An offset outlet can let a long channel sit on the desired wall while the connection lands in an available joist bay. Its distance from the end and its orientation depend on the model. Lay the drawing over the framing plan both ways. If neither orientation clears the joist, give that drawing to the plumber and builder to consider another location or body. Leave structural changes to a professional who can evaluate the framing.

Make a side view as well. Give the setter a sample of the actual floor tile and ask them to show the finished bathroom floor, shower entry, lowest tile and grate on the same elevation drawing. For a worked example, the mortar bed section of Laticrete's sheet specifies a quarter inch of fall per horizontal foot toward that drain. A four foot run at that pitch drops one inch. That inch is the difference between the high and low tile surfaces. In this detail Laticrete calls for the low tile to finish one sixteenth of an inch above the grate. Space for the drain body, support, joint and pipe still has to fit beneath the low end.

A four foot horizontal run spans the high and low tile edges, while the grate sits below the low edge. 4 feet of horizontal run 1 inch fall Tile surface Grate
Measure the fall between finished tile edges. In this HYDRO BAN detail the low tile edge sits another one sixteenth of an inch above the grate. The vertical spacing is exaggerated for clarity.

Keep the run and the channel length in different boxes on the sketch. On a rectangular shower, turning the same channel onto a different wall can change the run without changing the part length. If the difference at the threshold no longer fits the adjoining floor, ask the installer to draw the alternative before any demolition. A thinner grate cannot recover an inch needed for the slope, and removing floor structure is a separate design decision.

Does the drain belong at the back wall, the middle or the door?

A back wall drain gives water a downhill path away from an open entry when the shower floor is designed that way. Look at where the head aims and where your body deflects spray. A spray aimed directly at the opening can wet the bathroom before it ever lands on the sloped tile. Move the spray direction or consider a screen with the enclosure designer. At the other end of the room, leave sufficient clearance to lift the grate beside that new screen or a built in bench.

A center channel can be worth drawing when the trap is already near the middle, when there is a bench at the far wall, or when two sides must feed one line. Compare the outlet location on the drawing with the actual pipe before assuming you save plumbing work. An existing center pipe can also favor a point drain with an envelope of cuts around it. Ask the setter for both tile layouts if you care more about keeping that pipe than about the shape of the grate.

An entrance drain has a harder job. Water can pass each end or land outside the opening. Schluter's October 2026 Shower System Installation Handbook recommends that the intake openings of its original KERDI LINE span as much of the opening as possible at an entrance. It names the Solid, Pure and tileable D options and notes that the drying area may need secondary drainage. The same handbook says it does not recommend KERDI LINE VARIO at the entrance. Use the full model name, grate choice and drawing together when discussing an entrance drain.

For a doorway example, draw a 36 inch opening and center an 8 inch rectangle on it. Even treating every inch of that rectangle as an intake would leave 14 inches at each side. The actual openings may be shorter still. What feature would keep water crossing those strips inside the shower? If the plan cannot answer, reconsider the position, the entry design or the drain. Also have the designer mark how far the waterproofing extends outside any open shower and how the door or curtain changes the spray path.

If someone uses a wheeled shower chair, put the direction of travel on that same drawing. Ask about the finished transition, slot size and direction, grate support and the space to turn. For a project covered by US accessibility standards, the US Access Board's guides to floor openings and bathing rooms explain why elongated openings and the entry threshold need review. Give the designer the exact grate drawing. A level looking photograph cannot show how a small caster will cross the openings or whether the complete layout meets the requirements for that project.

Can the drain take all the shower outlets you use?

Start at the controls. Can the overhead shower and the hand shower run together, or does the diverter select one at a time? Write down the published flow of each outlet in gallons per minute and circle combinations the valve allows. In a hypothetical shower with two outlets rated at 2 gallons per minute each, using both gives a planning total of 4 gallons per minute. If the valve only switches between them, the corresponding figure is 2. The actual delivery depends on the supply and valve. Give the plumber the fixture sheets and the combinations, including body sprays if fitted.

Then ask for the drain maker's limit for the precise assembly. Schluter's US VARIO flow guidance describes that model for a single standard head delivering up to 2.5 gallons per minute and directs higher input projects to its original KERDI LINE. The hypothetical 4 gallon combination falls outside that VARIO guidance. Switching to a longer version of it would leave the same design limit. Ask for the capacity of the alternative in the intended installation, including the grate and the water depth used in any quoted test.

That depth matters at a low entry. Infinity Drain says its published figures assume a half inch head of water. A capacity measured with water standing above the intake assumes some pooling. Ask the installer to compare the test condition with the level at which water could leave your shower. A drain body also empties into a trap and waste piping. Have the plumber verify the actual pipe size, material, connection and venting against the design and local requirements. If the catalog gives only the cover dimensions, record the capacity as unknown. A longer slot or a bigger square at floor level cannot supply a missing flow rating.

Which covers are you actually comparing?

Look at the style selector on Home and Tower's 8 inch brass linear drain, model FD002. There are five choices. Brushed and matte black are the two tile insert covers. Brushed, chrome and gun gray are the three open bar grates. Brushed appears twice because you can have that finish with either face. If your sample board shows brushed metal and a continuous tile pattern, specify the brushed tile insert cover. A request for brushed alone leaves the supplier two different answers.

FD002 option What the listing establishes
Brushed or matte black tile insert A recessed cover for a tile piece. The supplier drawing shows an 18 mm top frame height.
Brushed, chrome or gun gray grate Open bars across the face. The supplier drawing shows a 9 mm top height for the grate version.

The listing gives the same 200 by 80 millimeter top footprint for all five choices. The top height in that drawing does not give the insert pocket depth, the accepted tile thickness or the overall space needed below the floor. The listing leaves the pipe size, fixing method and flow rating open. It also gives no installation steps for making a waterproof connection. Send the installer the selected style and request its section drawing, membrane detail and capacity. If those cannot be verified for your shower, choose an assembly for which the maker can supply them.

For a square comparison, Home and Tower's 4 inch full stripe grate, model FD004, has a chrome option with slots across the face and a removable hair filter shown beneath. The separate chrome washing machine model FD006 has a capped hose port in the middle. Both listings give a 100 millimeter square top. The hose port identifies the laundry version, and matching chrome finishes do not make the bodies interchangeable. The flat cover on another 4 inch square listing also lacks a confirmed tile insert tray. If you want to set tile into a cover, look for that feature on the chosen variant and get the permitted tile build up before cutting your sample.

Will you be able to lift and clean the cover?

Think through cleaning with the shower finished. At the display or on a sample, find the lifting point and the tool the maker specifies. See where the cover can be set down without striking glass or chipping its tile. On a linear drain, check both ends for access and check that the tray can come out from under any bench overhang. Ask who will keep the lifting key. Laticrete supplies a key with its HYDRO BAN linear grates and a hair strainer with its troughs. Verify both pieces in the specific system you select.

For an installed shower, use the grate maker's release method and clear only the parts intended for routine removal. Pick hair off the screen into the trash, clean the accessible channel as directed and put the parts back with the grate fully supported. If a cover is grouted in, has an unfamiliar lock, or resists its normal lifting tool, stop and identify the assembly. Levering against the tile can damage an edge or the support you hoped to keep. Schluter calls for mild cleaning of its stainless surfaces and excludes abrasives and cleaners containing chlorides. Check the care sheet for a coated or plated finish before using a cleaner from the tile cupboard.

What happened during the last ordinary shower is often enough to narrow the complaint. A small puddle behind one tile while the rest of the floor empties points the setter toward a local low spot or a raised edge. Water rising directly over the intake during normal use calls for checking the accessible screen and the drain path. If water rises again with a clean screen, have the plumber investigate the piping and the water entering the shower. If another fixture sends water back through the drain, stop using the affected fixtures and call for plumbing service. Changing the grate pattern would leave that problem in place.

What should the installer demonstrate before the job is closed?

Arrange to see the drain body and waterproof connection before tile hides them. Ask the installer to photograph the connection, wall corners, channel ends and entry and identify the products in the photos. Ask about two separate checks. One checks the drain connection to the waste pipe. The other checks containment by the waterproof assembly. Schluter's October 2026 handbook recommends a water test before tiling and a wait of at least 24 hours after completing its membrane installation before starting that test. That wait is for curing. The test duration and procedure are a separate matter for the selected system and local inspection.

If the water level falls unexpectedly or there is dampness outside the test area, have the installer stop, determine the cause and repeat the appropriate check after the repair has cured. Leave tiling on hold until the result is clear. Keep the documented results with the model numbers. A successful containment test cannot show that the final tile will guide water around the ends of the grate. Once the shower is complete, cured and cleared for use, have the installer show where water travels under ordinary use and where the cover lifts for cleaning.

Your next step

Take the floor plan, a tile sample and the permitted spray combinations to the plumber and setter. Ask them to mark the finished opening, drain outlet, membrane connection and finished heights on one drawing. With those choices settled, compare the cover styles in our floor drains collection. Keep the model and drawing together so the person fitting the grate and the person cleaning it later can both identify what belongs there.