Bathroom Questions › Bathroom Faucets
Bathroom Questions › Waterfall Bathroom Faucets
Bathroom Questions › Single Hole Bathroom Faucets
Bathroom Questions › Widespread Bathroom Faucets
Bathroom Questions › Bathtub Faucets
Bathroom Questions › Shower Systems
Bathroom Questions › Shower Heads
Bathroom Questions › Shower Doors
Bathroom Questions › Drains and Plumbing Parts
For a wall to wall linear drain, choose a system that can collect water across the finished width at the drain line. A shorter drain can work inside the shower if the tile beyond both ends slopes into the opening. Measure between the surfaces that will actually face each other there. The width on the shower plan, the length of the removable grate and the space the drain body needs underneath can all be different.
If the existing drain is loose, water is leaking below or wastewater is coming up, leave the shower out of use and have a plumber inspect it. You can take the measurements for a new drain from a plan or a dry opening.
Mark the drain line on the floor. If it runs across the back of the shower, measure side to side at the back, close to floor level. Take a second reading at the front edge of the proposed channel. Walls can taper across its width. Keep both measurements if they differ. A rigid rectangle that clears the walls at its back edge can still bind at one front corner.
If the walls are open, identify what your tape touches. A measurement between studs still includes the space the wallboard will occupy. A measurement between installed boards already accounts for the boards. Use a sample of the planned wall assembly to find the remaining buildup on each side, including the setting bed and any waterproofing still to come. If the finish changes to thicker stone on one wall, update that side of the calculation.
Suppose you measure 48 inches between wallboard faces. The planned layers bring the left wall inward 1/2 inch and the right wall inward 5/8 inch. That leaves 46 7/8 inches between tile faces. Write all three numbers on the sketch. The finished span tells you what the eye will see. The board measurement helps the installer check the wider metal parts that will sit below the tile.
Oatey's drawing for its 44 inch QuickDrain ProLine body, UPC 038753010069, gives 44 inches from end to end of the trough opening and 46 inches across the outside edges of the flange. The flange is the rim where the waterproofing connects. The outlet center sits 19 inches from one end of the opening and 25 from the other. If the plumber measures 19 inches from the outside edge of the flange instead, the pipe mark will be off by an inch.
This assembly uses separate trough extensions to reach the sides and a removable cover cut to the finished opening. Oatey's installation guide has the setter measure each end of the trough to its wall for the extensions, then measure the tiled width for the cover. If the two end spaces differ, keep them as a left measurement and a right measurement. Dividing their sum by two would give you two pieces of the wrong length.
Buying the cover needs one more check. Oatey's February 2024 ProLine drawing lists 48 inch cover stock for this body, while the product listing for the same UPC calls for 56 inches. Send Oatey the actual finished width, cover pattern and body number, and ask for the matching cover part number. A 48 inch blank cannot yield a cover longer than 48 inches, and a longer blank still needs its supports in the right places. Oatey allows the cover to be trimmed and prohibits modifying this drain body.
Infinity Drain gives a different calculation for its Site Sizable PVC series. Take the 48 inch S LAG 65 kit, model 6548. First have Infinity Drain match the instructions to the outlet section and end caps supplied. Its product page still links a February 2022 sheet that gives 2 7/16 inches for the outlet and describes 3/16 inch for both caps. Its installation library carries an April 2026 sheet that names the same series and gives different dimensions.
If the maker confirms the April 2026 sheet applies to your parts, the outlet section adds 2 13/16 inches to the channel length and each end cap adds 3/16 inch. Suppose the installer has established a target of 47 3/16 inches for the assembled channel. The straight PVC pieces together need to supply 44 inches. Have the installer check the actual fitting widths and how far each channel piece seats before marking the cuts, then fit the assembly together dry to verify the overall length before bonding.
The grate gets its own measurement. In those same instructions it is cut 1/8 inch shorter than the inside length of the assembled channel so it can lift out. The assembled outside length cannot give you that inside measurement. If the supplied pieces or their instructions disagree with either measurement, set the saw aside until the maker identifies the correct dimensions.
If your drain comes up short, trace where water from the last tile will go. In a curbed shower with a drain against the back wall, ask the setter to mark the tile cut and direction of fall at each end. A straight slope toward the wall will send water from the far corner onto the tile beside a short channel. If the setter cannot give that corner a downhill path into the opening, look for a longer compatible assembly or change the floor layout before setting tile.
At an open entry, check the two ends against the opening. Infinity Drain recommends a full span across the threshold and advises against some narrow channels and tile insert designs there. Ask which intake and cover the maker supports at the entrance. If the available length leaves a route into the bathroom, choose a suitable full span model or have the designer move the drain and direct the floor back into the shower.
The Chrome grate version of Home and Tower's FD002 illustrates the limits of a catalog size. The supplier gives 200 millimeters across the long dimension of its top, about 7.9 inches. The listing offers different cover styles at that length and gives no instructions for cutting or joining bodies. Set two paper marks 200 millimeters apart on your drawing. If the floor outside those marks needs a channel to catch the water, specify an assembly with a documented length and waterproofing detail for that job.
Keep the sketch with the exact body and cover numbers so the plumber and tile setter can check the same endpoints before work begins. If glass will close off this opening, measure for the shower door at the door location as well. Use the shower floor drain guide to check the proposed assembly against your floor and waterproofing.
Brass Linear Shower Floor Drain with Tile Insert Cover or Bar Grate 8 Inch in Five StylesFrom 1.618,00 kr
Square Brass Washing Machine Floor Drain with Stripe Grate and Hose Elbow 4 Inch in Four FinishesFrom 1.190,00 kr
Square Brass Floor Drain with Round Slotted Cover and Anti Odor Core 6 Inch in Two Finishes1.667,00 kr
Square Brass Shower Floor Drain with Full Stripe Grate and Hair Filter 4 Inch in Four FinishesFrom 1.176,00 kr
Square Brass Floor Drain for Shower and Bathroom with Flat Cover 4 InchFrom 1.155,00 kr