FREE SHIPPING OVER $20010% off code: HOME10Buy Now Pay Later AVAILABLE AT CHECKOUT

What size P trap for a bathroom sink?

A 1 1/4 inch tubular P trap is a common choice for a bathroom sink. A 1 1/2 inch trap can also fit a 1 1/4 inch tailpiece when the trap maker supplies the appropriate reducing washer and the outlet matches the wall connection. Look under the sink before picking either size. You need to identify the tube coming down from the basin and the connection that receives the arm at the wall.

Dimension ticks mark the outside widths of the straight tailpiece and outlet arm where they are clear of the fittings. Two sizes to identify under the basin Tailpiece width Inlet nut Outlet tube width Wall Adapter Measure the tube clear of the fitting.
Measure across the outside of each straight tube, clear of its nut or adapter. Check the wall adapter separately to confirm which outlet tube it accepts.

Which part should I measure below the sink?

Measure the tailpiece. Open the vanity and trace the drain downward from the bottom of the bowl. Find an exposed length of straight, smooth tailpiece above the trap inlet. A caliper held gently across the outside gives the diameter. With a ruler, sight straight across the tube through its center. Take the reading away from the nut, threads, flared ends or any decorative collar. Measuring across the nut tells you how wide the nut is, while the trap specification describes the tubing it accepts.

Identify the wall connection. Follow the curved trap up and across to the wall. Look for markings on the trap, the straight outlet arm and the adapter at the wall. Take one photo showing the entire bend and another that captures the lettering and the joint. A wide decorative plate can hide the point where the tube joins the plumbing. If the adapter is hidden or the finish is too worn to read, record the outlet arm diameter and ask the installer what receives it. Leave a sealed wall connection intact while identifying it.

What does a marking of 1 1/4 by 1 1/4 mean?

Kohler's 8998 is an example with both connection sizes stated. Its specification sheet identifies a 1 1/4 inch by 1 1/4 inch trap, a slip joint at the inlet and tubing at the outlet. Think of it as two checks on a purchase list. The incoming tailpiece needs the specified inlet. The receiving wall connection needs to accept the specified outlet tubing. A match at the sink answers only the first check.

The opening in the basin itself answers a different question. For example, Kohler lists a 1 3/4 inch drain hole on the Caxton 2210 sink and recommends its 8998 trap. The drain fitting seats in the larger hole in the ceramic. The trap connects farther down, after the drain fitting and its tailpiece. Measuring across the empty sink hole would send you looking for a trap size that the maker never specified for that connection.

Can the inlet and outlet require different sizes?

Yes. Consider a vanity where the existing tailpiece measures 1 1/4 inches across and the wall adapter accepts 1 1/2 inch tubular stock. Oatey's HDC9682 has a 1 1/2 inch outlet and accepts either a 1 1/2 inch or a 1 1/4 inch inlet. For the smaller tailpiece it comes with a reducing washer. The washer fits around that smaller tube at the inlet. It has no effect on the diameter of the outlet arm going into the wall.

Now change just one detail. Suppose the existing wall adapter accepts only a 1 1/4 inch outlet arm. The same Oatey kit still accepts your tailpiece, yet its 1 1/2 inch outlet cannot enter that adapter. Trying another inlet washer will not change the outcome. Have the installer confirm a trap with the correct outlet or specify a compatible wall connection. This is why a package marked for bathroom sinks can be the wrong replacement even when the inlet size matches perfectly.

What you can identify What to confirm
Both straight tubes are 1 1/4 inch tubular. Check a 1 1/4 inch trap with the right connection style and enough reach for the existing wall fitting.
The inlet tube is smaller than the 1 1/2 inch trap arm. Look up the exact trap. Identify the maker's reducing washer and check which end takes it.
The pipe at the wall is marked Schedule 40. Identify the adapter that joins this pipe to the tubular arm. The two parts can carry the same nominal size and still need that transition.

What if my trap uses a decorative bottle and a metric tube?

Ask for a dimensioned drawing and the type of joint at each end. For the Brushed stainless selection of the Home And Tower bottle trap kit, the supplier drawing shows the inlet tube and wall pipe each 31.5 mm across. The collar is 40 mm across. The listing gives no thread size. A ruler that looks close to 1 1/4 inches at the tube does not tell you the collar thread or establish that the kit will seal in your wall fitting.

To check the reach under an exposed basin, mark the height of the wall opening's center and the height of the lower end of the tailpiece from the same reference. Measure from the face of the wall adapter to the centerline of the tailpiece, and note any offset to the left or right. Send those measurements and the connection photos to the installer before choosing a finish. A diameter match still leaves the question of whether the pieces can meet without pulling the basin drain sideways. If the proposed layout changes the fixed plumbing, have the installer verify the connection and the locally applicable requirements for that layout.

For measurements at the bowl, see how to size the bathroom sink drain. For a diagram of what the bend does once the trap is connected, read how a P trap works. The bathroom sink drain guide covers the fittings above it.

Drains and Plumbing Parts in stock

See all drains and plumbing parts