FREE SHIPPING OVER $20010% off code: HOME10Buy Now Pay Later AVAILABLE AT CHECKOUT

How to install a towel bar without studs

You can install a towel bar between studs if its maker allows hollow wall mounting and every bracket can fasten to sound wallboard with the specified hardware. Check both ends before making the first hole. For a shower wall, confirm how every penetration will be sealed, too. If the bar needs wood backing, or you cannot establish what is behind the wall, use a freestanding towel stand or have an installer provide the backing the bar requires. Choose a position where nobody will reach for the rail to steady themselves. Anyone who needs a handhold needs a grab bar installed for that purpose.

What is behind each bracket?

Start on a dry interior wall. Tape up the template for your exact bar, level it, and mark every screw position in pencil. A mark for the center of a decorative post can sit over a stud while one of its screw holes misses the wood. Compare the marks with construction photos, plans or an accessible view from the other side. Identify the wall material, its thickness, the space behind it and the path of any wiring, pipes or other services. Include the space the anchor needs to open and the full reach of the drill and screw.

Bosch's DTECT120 scanner instructions warn that a green reading can miss a hazard. Bosch calls for checking other information and isolating electrical power, gas and water before penetrating the wall. If you cannot establish the routes and safely arrange the necessary shutoffs, have a qualified installer check the site. Keep the wall intact while you find out.

Board thickness and open space answer different questions. For example, the TOGGLER TB plastic anchor fully opens behind wall material 3/8 to 1/2 inch thick and needs 3/4 inch of space behind it. Suppose you know the drywall is 1/2 inch thick but there is only 1/2 inch between its back face and masonry. The board meets that anchor's grip range. The cavity is too shallow to install it as a hollow wall toggle. Those dimensions belong to the TB. Get the dimensions for the fastener approved for your own bar before laying out holes.

The drywall fits the example toggle but masonry blocks the space needed behind it. A shallow cavity seen from above Drywall Masonry Room Cavity 1/2 in 1/2 in TB toggle needs 3/4 in behind drywall
Measure from the room face to the back of the board for grip, then from the back of the board to the obstruction for clearance. This location fails the second check for the TB anchor.

Which fasteners belong to this bar?

Set the actual plates, screws and anchors beside the instructions. A difference in the hardware is a reason to pause even when the model number matches. For Moen's Preston DN8418CH, the older BA1047 sheet describes anchor screws that cut their own way into drywall through the mounting plate. Moen's currently linked INS12123 sheet shows separate screws and plastic anchors. It calls for 1/4 inch holes at the oval marks before the plate goes on. That sheet gives no wall thickness or list of suitable substrates. Ask Moen about your wall if that is the kit you have. Applying the older method to the newer parts would skip the anchor entirely.

Consider the Double bar brushed gray option in Home And Tower's stainless steel double towel bar listing. A photo shows the gray bar laid out beside four white plastic anchors, four screws and a hex key. It gives no installation steps or hole spacing. A photograph cannot tell you what those anchors will grip. Before committing to that location, ask for the approved wall construction and attachment details for the double bar. A bar sold with explicit drywall instructions may be a better fit for a closed wall.

How do I fit a bar approved for drywall?

Moen provides a worked example in sheet INS13382A for the Bolt collection. The BH5433CH kit includes a 24 inch bar. Its drywall instructions use folding plastic toggles and a setting pin. Use the following sequence only with the matching hardware on a verified, suitable drywall site.

1. Match the template to both plates. Identify the towel bar marks for the correct length, check the level again and tape the template flat. Hold the plates at the marks to check their orientation. If an old hole is oversized, ragged or in a soft patch at any screw position, reject that layout. A decorative cover or a skim of filler can hide damage while leaving little for an anchor to grip. Move the complete template to sound material clear of the damaged area or arrange a backed repair first.

2. Seat and activate the toggles. For this Bolt kit, Moen calls for two 5/16 inch holes at each plate. Wear eye protection. Follow the marked locations, remove the template and fold the ends of each specified toggle together to put it through its hole. Tap the anchor lightly until flush. Insert the supplied pin, tap it lightly as Moen directs to activate the toggle, then remove it. Repeat for each anchor. If one will not seat or activate, leave the bar off. Have the obstruction or wall thickness checked before proceeding.

3. Attach the plates, then the posts. Loosen the setscrews to free the plates. Fit each plate with the UP mark facing you and oriented as shown on the template. Run the screws through the plate into the activated anchors. Stop if an anchor spins, the plate rocks or the face of the drywall starts to crush. Once both plates sit firmly, fit the posts and rail and secure the setscrews underneath. A post that will not engage calls for a second look at the plate orientation and spacing. Pulling the posts together with the screws can hide a misplaced plate.

What if one end lands on a wood stud?

Read the instructions for each end. For its discontinued Dryden 75118, Delta's sheet 102880 expressly allows one or both ends on studs. At a verified wood stud it specifies two supplied screws through the bracket. For the end over hollow drywall, it says molly or toggle bolts may be needed and directs you to source them separately. Confirm the fastener fits the other bracket and the wall before drilling either end. If the instructions for your bar require backing at every plate, finding one stud still leaves the other end without the support it needs.

What changes on a shower wall?

A tile surface raises a separate waterproofing question, even with sound backing. If the wall uses Schluter KERDI, the Shower System Installation Handbook calls for a seal wherever a fastener pierces that membrane. Before drilling, get the approved fastening and sealing detail for the actual wall system. A bead around a decorative cover leaves the screw path behind it unaccounted for. If an old hole may already go through a shower membrane, keep the shower out of use until the installer has assessed and repaired it. For an undisturbed wall with an unknown system, move the towel to a stand in a dry spot.

If you have established what is behind the tile, check how to drill the finish without cracking it. If you need a different wall, compare towel bar, ring and hook locations before you move the template.

Towel Bars and Racks in stock

See all towel bars and racks