A common design slope for a tiled shower floor is 1/4 inch down for every horizontal foot toward the linear drain. At that pitch, a tile edge 3 feet from the drain sits 3/4 inch above the tile beside the inlet. Confirm the slope for your shower with the installer and local building department before setting the drain height. If the drain body shifts or you see a leak below, leave the shower off and have the leak or loose fitting inspected.
If wastewater rises through the grate, keep everyone clear of the affected area. Stop using fixtures and appliances that send water down any household drain and contact your local sewer utility or a plumber. On a dry, sound shower floor, you can take all the measurements below without turning on the water.
Section P2709.1 of the 2024 International Residential Code gives a range for the finished shower floor. It calls for an even fall toward the drain of at least 1/4 inch and at most 1/2 inch per foot. That is a model code. For an example of the difference an address can make, the building division in Vallejo, California, lists 1/8 to 1/2 inch per foot for the finished shower floor in its residential bathroom remodel bulletin, citing California Plumbing Code section 408.6. Ask which edition and local amendments apply to your permit. The drain system can call for a particular pitch within the allowed range.
If someone will roll into the shower, have the designer mark the shower floor, the entry and the clear space for maneuvering on the plan. The US Access Board's guide to the ADA Standards recommends a maximum slope of 1 in 48 for a roll in shower floor. That works out to 1/4 inch per foot. Here the number describes how steep to make the surface at most. The residential model code uses the same number as its minimum for drainage. Have the designer confirm the accessibility requirements for this particular project before adding extra pitch to help water run off.
On a rectangular floor with a channel across the entire back wall, measure straight toward the inlet from the opposite tile edge. Use the horizontal distance on the plan. Running the tape across the room parallel to the grate gives the length of a different side. Multiply the run in feet by the specified drop per foot. For example, if the tile run is 42 inches, divide by 12 to get 3.5 feet. At 1/4 inch per foot, the far tile must finish 7/8 inch higher than the tile beside the drain.
At an interior channel, work out the runs separately. Suppose the floor extends 36 inches on one side and 18 inches on the other. To get 1/4 inch per foot on both, the outside edges would be 3/4 inch and 3/8 inch above their respective low tile edges. If both low edges are at the same height and the setter marks both outside edges at 3/4 inch, the short side becomes twice as steep. Ask for a section through that side before agreeing to a level line of wall tile all around the shower.
Suppose the setter takes four readings a foot apart on one line, using the tile beside the inlet as zero. An even 3 foot run at the example pitch would read 3/4, 1/2, 1/4 and zero inches, starting at the high end. In the drawing the middle readings are 3/8 and 1/2. Follow them toward the grate. Water in the dip has to climb 1/8 inch to get past the next tile. A level held across the two ends can miss that pocket entirely.
Measure the dry surface in shorter sections. Set the high end of a 24 inch spirit level on the tile with the other end toward the drain. Lift the low end until the bubble centers, then measure the vertical gap directly beneath that end. An even 1/4 inch per foot gives a 1/2 inch gap over 24 horizontal inches. Take readings on tile faces, clear of recessed grout joints. If the level rocks on a high edge, or an end points uphill, mark the spot on a sketch for the setter.
Check the path where the water actually sat. Repeat along the left and right sides as well as down the middle. A crosswise joint or a small tile at the end of the channel can interrupt just one path. Use a shorter straightedge across that spot to locate the ridge. A photo of the ruler, the two tile edges and the inlet gives the setter more to work with than a picture of a wet floor alone.
Figure 1 in the August 2025 instructions for Laticrete's HYDRO BAN Linear Drain shows the installer setting the channel level. The channel has its own internal shape to carry water, while the mortar bed around it pitches toward it at 1/4 inch per foot. With a factory sloped tray, the preparation is different again. Schluter's October 2026 Shower System Installation Handbook calls for any subfloor leveling before its KERDI SHOWER LT or LTS tray goes in. A tray laid across a floor that tilts against it can lose some of the fall molded into it.
Use the finished tile beside the opening as the low point for your calculation. For the Gun gray grate version of Home and Tower's FD002, the supplier gives 9 millimeters as the height at the top of the bar grate. That measurement cannot tell the plumber how far below the finished floor the body or its connection will sit. Get the installation section for the exact drain before fixing that height. If the maker cannot provide one, choose a documented assembly while there is still room to change it.
Keep the tile readings with the installer's record of the waterproofing inspection or test. A liner can hold test water even if the tile laid above it later has a dip. Ask the setter to address any reverse slope before accepting the floor. If your planned falls will not fit at the doorway, compare other linear drain positions and bring the revised heights to the installer with the shower floor drain guide.
Brass Linear Shower Floor Drain with Tile Insert Cover or Bar Grate 8 Inch in Five StylesFrom 1.618,00 kr
Square Brass Washing Machine Floor Drain with Stripe Grate and Hose Elbow 4 Inch in Four FinishesFrom 1.190,00 kr
Square Brass Floor Drain with Round Slotted Cover and Anti Odor Core 6 Inch in Two Finishes1.667,00 kr
Square Brass Shower Floor Drain with Full Stripe Grate and Hair Filter 4 Inch in Four FinishesFrom 1.176,00 kr
Square Brass Floor Drain for Shower and Bathroom with Flat Cover 4 InchFrom 1.155,00 kr